Medium frequency induction coil, furnace scale

by:Hengyang Furnace     2020-10-11
Medium frequency induction coil, furnace scale technology an intermediate frequency induction coil, furnace leakage but blowing in normal will have any questions, please answer: under high voltage on both ends of the intermediate frequency induction coil, for the medium frequency power supply of 380 v into line, at least as high as 700 v on both ends of the sensor, and if the intermediate frequency smelting furnace, is likely to be using times pressure method, the voltage is 700 v twice! Once the induction coil, leakage will produce a serious safety accidents, must immediately stop the maintenance. Position the circular on medium frequency induction coil, furnace into line what is the role of medium frequency induction coil, furnace scale a: medium frequency induction coil, furnace circular function search information local pictures pictures link submit answer anonymous answer automatically saved in your answer be adopted after will receive: system rewards (15 Wealth value + growth) 20 (+ problem Wealth value. A ton of intermediate frequency electric furnace size medium frequency induction coil, induction coil, furnace scale a: 72 cm. How the magnetic field of induction coil, intermediate frequency furnace medium frequency induction coil, furnace scale a: won't be charged. Outside induction electromagnetic induction coil, but there is no form in the magnetic field near the metal loop. Assuming that connected by a wire, the wire will also become a part of the metal, without and metal formed in magnetic circuit, so near the metal will not charge. Voltage values in the intermediate frequency induction coil, furnace is a: how much for the resonant circuit and coil in series circuit, the resistance, capacitance and inductance in the series circuit, a power, voltage, current and phase phenomenon, called series resonance, its characteristic is: the circuit is purely resistive, power, voltage and current with phase, reactance X equal to zero, the impedance Z is equal to the resistance R, the impedance of the circuit at this time the minimum, the maximum current, on the inductance and capacitance. Medium frequency induction coil, furnace voltage matter how many intermediate frequency induction coil, furnace scale a: bring to earth voltage of the transformer a few volts, induction coil, is safe, encounter is not hemp feeling ( Our) 1000 v, without transformer. The rhyme hai-yong wang. Medium frequency induction coil, furnace leaks can use soldering? Answer: didn't lead can use tin welding, oxygen welding is not used on the tin. Excuse me one and a half tons of intermediate frequency induction coil, furnace is 75 o use what size of the tank? A: such as topic two problems; 1 is 250 kw is not correct, for the apparent power kva should be 250 kva transformer unit, 2 is 05 t refers to the intermediate frequency furnace volume is not power, power factor is 1, if this furnace load the transformer load for 1 hour, then about 250 KWH electricity ( C) 。 Medium frequency induction coil, furnace blasting is how to return a responsibility? A: coil short-circuit phenomenon, may be a metal debris, this kind of phenomenon have lighter phenomenon, careful observation will find. Generally speaking, the new furnace can be ruled out. 30 tons of intermediate frequency furnace induction coil diameter answer: this has no fixed value, according to your industry, production of raw materials, production processes, supply ability, etc. , after a careful calculation. Medium frequency induction coil, furnace scale heating principle of intermediate frequency furnace technical data a: intermediate frequency furnace is mainly composed of induction coil, induction coil, power supply, and made of refractory material in the crucible. Within the crucible containing metal furnace charge, equal to each winding transformer, induction coil, when on ac power, to produce alternating magnetic field in the induction coil, the magnetic force line in the crucible furnace charge, metal is produced in the furnace charge induction electromotive force, due to form a charge itself. Medium frequency induction coil, furnace welding should choose what kind of welding rod, a: medium frequency induction coil, furnace welding should choose copper electrode. Scope: copper electrode main welding conductive copper platoon, catheter copper structure, etc. Copper electrode is generally round head, the general specification is 16202532. The characteristics of the commonly used copper electrode: T107 for red copper electrode, the atmosphere and seawater has good corrosion resistance, the main welding conductive copper platoon, catheter, such as copper. Medium frequency induction coil, furnace can emit blue fire use medium frequency induction coil, furnace scale a: this is when the oven, lining temperature reached 600 degrees, the crystallization water out of furnace lining, high temperature hydrogen was isolated, hydrogen discharge again combined combustion with air, the blue flames. After this phenomenon for lining sintering and crystallization water disappear naturally. As a common phenomenon in large and medium frequency melting furnace. The coil can be used again. Only when the oven is unfavorable for high power. 40 tons of intermediate frequency furnace with multiple intermediate frequency induction coil, induction coil, furnace scale answer: each company design is different, basically see drawings, to estimate the at least one coil number of turns of the specifications of the copper pipe inner diameter of the coil diameter turn spacing. Medium frequency induction coil, furnace external fire is how to return a responsibility, can also use medium frequency induction coil, furnace scale a: fire is to discharge furnace and without a solid wall. In the intermediate frequency furnace and induction coil series parallel capacitance work? A: for the resonant circuit and coil in series circuit, the resistance, capacitance and inductance in the series circuit, a power, voltage, current and phase phenomenon, called series resonance, its characteristic is: a pure resistive circuits, power, voltage and current with phase, reactance X equal to zero, the impedance Z is equal to the resistance R, the impedance of the circuit at this time the minimum, the maximum current, on the inductance and capacitance. Medium frequency induction coil, furnace replacement cabinet that need to be replaced, please answer: increase the rated power of the control cabinet must be at least 250 kw or more, that you open the original control cabinet, SCR, copper platoon, capacitance, there are not enough, all to increase, control circuit should be good. Or get a new save trouble, and warranty.
If you have a need for induction heating equipment induction heating furnace, like , and , you need to be able to find a dependable provider who you can trust when necessary.
Foshan Hengyang Furnace Manufacturing Co.,Ltd. offers a vast array of , and for all tastes and styles. When you want to kick your induction heating furnace with automatic feeder up a notch, you want Induction furnace, Induction melting furnace manufacturer, induction furnace manufacturers!
steel melting furnace is one of the best products sold in the market today.
Provide aluminum smelting furnace strategists with enough funds to adequately market our company and the products and services it provides.
Undoubtedly, induction electric furnace are made with advanced equipment.
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...