Intermediate frequency furnace after full frequency voltage 600 v

by:Hengyang Furnace     2020-10-10
Intermediate frequency furnace after full frequency voltage 600 v dc technology an intermediate frequency furnace high voltage? Intermediate frequency furnace after full frequency voltage 600 v a: you should think about how to put your grid power to raise a few? Intermediate frequency furnace is depend on the grid, working on the power of intermediate frequency power supply in the middle of the grid and the stove is a kind of transformation. Ac input, 380 v, dc voltage is 510 v (satisfying medium frequency furnace Static) , if the three phase voltage drop to 360 v, dc voltage is only about 486 v! Manual tuning. What are the common faults intermediate frequency furnace? Intermediate frequency furnace after full frequency voltage 600 v answer: 1, the startup system without any reaction (1) rectifier board failure; (2) over current, over voltage protection action; (3) the main switch is not together; (4) control tuning work potentiometer damage or break; (5) rectifier control power supply part of the bad. 2, only dc voltmeter has instructions, other no reaction (1) inverter board and inverter circuit fault; (2) the inverter power supply failure. No 22 v inverter pulse power supply. Note:. In the intermediate frequency furnace and induction coil series parallel capacitance work? Intermediate frequency furnace after full frequency voltage 600 v a: role: booster, in parallel to increase current. With coil in series for the resonant circuit, resistance, capacitance and inductance in the series circuit, a power, voltage, current and phase phenomenon, called the series resonance. Its characteristic is: the circuit is purely resistive, power, voltage and current with phase, reactance X equal to zero, the impedance Z is equal to the resistance R, the impedance of the circuit at this time. Intermediate frequency electric furnace intermediate frequency voltage exceeds 1800 v rectifier trip 1600 v no matter a: intermediate frequency CLP frequency voltage more than 1800 rectifier circuit was tripped, because you don't have enough wire square. Intermediate frequency furnace power supply voltage is how many intermediate frequency furnace after full frequency voltage is 600 v a: how much of a medium frequency electric furnace equipment. 005 t ~ 15 t intermediate frequency of complete sets of equipment, the power supply into line voltage 380 v, 500 kg of above can also be 720 v, line voltage is different. And furnace voltage is bigger. Baidu / / ningbo shekinah, intermediate frequency enterprise. A how much capacity of intermediate frequency furnace transformer after intermediate frequency furnace with intermediate frequency voltage 600 v answer: the characteristics of medium frequency furnace transformer harmonic, no fever, energy conservation, environmental protection, prevent short circuit, overload resistance is strong, fast melting. Compared with the conventional with the capacity of transformer, smelting time shortened by about 20%, tons of power consumption fell by around 80%, annual output is calculated at 3000 tons, can saving electricity each year about 300000 degrees. The product is suitable for below 30 tons of intermediate frequency furnace is special. High side voltage of 10 k. How to calculate the ratio of intermediate frequency furnace of frequency voltage and dc voltage, and a: the ratio of intermediate frequency furnace of frequency voltage and dc voltage is 1. Three times. Before the adjustment Angle of potentiometer. Dual power medium frequency electric furnace overloading won't start, particularly large, medium frequency current didn't answer: intermediate frequency technology problem, consult intermediate frequency electric furnace production suppliers, for example, ningbo divine radiation electric furnace. After intermediate frequency furnace with intermediate frequency furnace problem a: intermediate frequency voltage 600 v 1 lighter medium frequency furnace, if the light is capacitance may be a copper platoon line loose, capacitor terminal touch water be affected with damp be affected with damp, if furnace of flint, due to leakage magnetic field is very large, medium frequency furnace caused by nearby conductor, with a strong potential, an induction of induction electric potential difference between different conductor, when a moving conductor short-circuit potential difference, while lighter phenomenon, or when the different electricity. Consult ace, I take a medium frequency furnace. Phenomenon on dc as follows a: suggest to check the power first potentiometer, replacement of a look, if still or phenomenon, that is the other aspects. Series inverter circuits and parallel inverter circuit, for the circuit of the connection mode is different, the same failure phenomenon lookup aspect is different also. If it is a parallel inverter circuit, suggest you Jane after numerous search, first look at the furnace charge is added. Intermediate frequency furnace after full frequency voltage 600 v 750 kw intermediate frequency furnace technical data: voltage into the line of 380 v. Intermediate frequency voltage, electric current is how much a: x = 1732 x line voltage power line current active power factor x = = 750000 power/voltage/current ( 1732x380x08) = 14244 ( Ann) 。 Consult ace, I take a medium frequency furnace. Phenomenon after the following boot dc intermediate frequency furnace with intermediate frequency voltage 600 v a: suggest to check the power first potentiometer, replacement of a look, if it's still, it is the other aspects. Series inverter circuits and parallel inverter circuit, for the circuit of the connection mode is different, the same failure phenomenon lookup aspect is different also. If it is a parallel inverter circuit, suggest you Jane after numerous search, first look at the furnace charge is added. Intermediate frequency furnace with dc voltage without current answer: impossible without dc current, unless the current meter is broken, there was something wrong with furthermore voltage divider, reactor have voice: there must be an electric current passes through. To replace the SCR. Intermediate frequency furnace dc voltage is normal. Intermediate frequency voltage is normal. But direct current low intermediate frequency furnace with intermediate frequency voltage 600 v answer: after the large current and dc voltage down, slowly, see can increase the dc current?
Foshan Hengyang Furnace Manufacturing Co.,Ltd. has built its reputation on a commitment to providing quality products and services while rapidly responding to international needs for innovative products.
If you cannot find the specific type of that is best for your business in the above mentioned guide, you can visit Induction furnace, Induction melting furnace manufacturer, induction furnace manufacturers for the best consultants specializing in this field, who can recommend the your are looking for. Customization is warmly welcomed here.
can be used in a wide variety of ways.
Looking for Manufacturers in China? Then Foshan Hengyang Furnace Manufacturing Co.,Ltd. is the right choice. we are a well known aluminium shell furnace metal melting furnace Manufacturers and suppliers from China.
As consumers get more and better information regarding how to compare various products and companies, it is critical to compete on the price and value of electric melting furnace aluminum.
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...